Text Box: -
Text Box: +
Text Box: -
Text Box: +
Text Box: -
Text Box: +

Engine

Max
RPM

Alternator
Calibration

Magnetic
Pickup

Off RPM

On RPM

 

 

CAT 3176 360 HP

2100

 

118

1900

1500

 

 

CAT 3406 500 HP

2100

 

113

1900

1500

 

 

CAT 3412 E 650 HP

2100

 

136

1900

1650

 

 

CAT 3306

2100

 

156

1900

1650

 

 

CAT C-10,& C12

2100

 

113

1900

1650

 

 

CAT C-15, C 16

2100

 

136

1900

1650

 

 

CAT 3126B

2200

 

156

2100

1750

 

 

Cat/Perkins 26.1 HP

3240

 

96

2900

2650

 

 

Cat/Perkins 23.5 HP

3400

9

96

3300

2650

 

 

Cat/Perkins 33.7 HP

3240

 

109

2700

2400

 

 

Cat/Perkins 33 HP

2800

9.3

109

2700

2400

 

 

Cat/Perkins 50 HP

3025

9.4

126

2700

2400

 

 

Cat/Perkins 50 HP

2800

9.4

126

2700

2400

 

 

Cat/Perkins 60 HP

3025

 

126

2700

2400

 

 

Cat/Perkins 86 HP

2550

16.5

126

2300

2050

 

 

Cat/Perkins 88 HP

2500

16.5

126

2400

2150

 

 

Cat/Perkins 115 HP

2425

 

126

2300

2050

 

 

Cat/Perkins 115 HP

2500

16.5

126

2400

2050

 

 

Cat/Perkins 140 HP

2225

 

126

2100

1800

 

 

Cat/Perkins 125 HP

2400

16.5/17.1

126

2300

2050

 

 

Cat/Perkins 180 HP

2525

 

126

2400

2150

 

 

Cat/Perkins 188 HP

2500

14.5

126

2400

2150

 

 

Cat/Perkins 250 HP

2100

 

154

2000

1600

 

 

Cummins 3.3 65 HP

2500

 

110

2400

2150

 

 

Cummins 3.3 85 HP

2500

 

127

2400

2150

 

 

Cummins 4B & 6B 80/200 HP

2500

17

159

2400

2150

 

 

Cummins 6CTA 250 HP

2100

20

158

2125

1800

 

 

Cummins B 80, P100, B 116

2500

17

159

2400

2150

 

 

Cummins P 125

2500

17

159

2350

2100

 

 

Cummins B130, PP173, QSB205, B200

2500

 

159

2400

 

 

 

Cummins QSM11400, QSX15 525, QSK23 760

2100

 

118

1900

1650

 

 

Cummins QST23 960

2100

 

 

1900

1650

 

 

Cummins QST30 1000

2100

 

 

1900

1650

 

 

All Duetz Engines

2800

12.5

 

2700

2400

 

 

Ford 4 Cyl. 70 HP

2800

14.5

 

2700

2400

 

 

Ford 6 Cyl. 119 HP

2800

15.3

 

2700

2400

 

 

G.M. 3.0 L / 4.3 L

2800

19

 

2700

2400

 

 

Hatz 35 HP

2800

12

 

2700

2400

 

 

Honda 20/24 HP

3600

3

 

3300

2650

 

 

John Deere 80/170 HP

2500

16

129

2400

2150

 

 

John Deere 180/250 HP

2200

16

129

2150

1770

 

 

John Deere 80/170 HP

2500

 

129

2400

2150

 

 

Kohler 25/27 HP

3400

9

1

3300

2650

 

 

Kubota 49 HP

2800

9 or 12

 

2700

2400

 

 

Lombardini 25 HP

2800

5

 

2700

2250

 

 

Lombardini 57 HP

2800

13

 

2700

2400

 

 

Wisconsin 30/35 HP

2800

Ignition Coil “-” CAL 2

24

2700

2400

 

 

Wisconsin 37 HP

2400

Ignition Coil “-” CAL 2

27

2300

2050

 

 

Wisconsin 65 HP

3000

Ignition Coil “-” CAL 2

 

2900

2650

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

· To prevent mistakes, the user must go through all SEVEN steps or program will not set. See back for troubleshooting guide. 

· If, after starting to set the unit, no entries are made after 7 seconds, the unit will go back to the last program setting. 

· So, if you make a mistake, not to worry, it will just go back to the last set program. If you need help, just call!

Text Box: Operating Instructions
 Please Read Before Operating
Text Box: Warranty: Electronic Solutions of Harrison, LLC and/or it’s subsidiaries and it’s affiliates (“the Manufacturer”) warrants its products, hereafter referred to as “the Product” or “Products,” to be in conformance with its own plans and specifications and to be free of defects in materials and workmanship under normal use and service for a period of twelve months from the date of shipment by manufacturer. The Manufacturer’s obligations shall be limited within the warranty period, at its option, to repair or replace the product or any part thereof. The Manufacturer shall not be responsible for dismantling or reinstallation charges. To exercise the warranty the product must be returned to the manufacturer freight prepaid and insured.  
This warranty does not apply in the following cases:  Improper installation, misuse, failure to follow installation and operating instructions, alteration, abuse, accident, tampering, power washing, or welding and/or repair by anyone other than the manufacturer.
This warranty is exclusive and expressly in lieu of all other warranties, obligations or liabilities, whether written, oral express or implied, including any warranty of merchantability or fitness for a particular purpose or other wise.  In no case shall the Manufacturer be liable to any one for any consequential or incidental damages for breach of this warranty or any other warranties whatsoever, as aforesaid.  
This warranty shall not be modified, varied or extended, and the Manufacturer does not authorize any person to act on its behalf in the modification, variation or extension of the warranty.  This warranty shall apply to the Product only.  All products, accessories or attachments of others used in conjunction with the Product, including batteries, shall be covered by their own warranty, if any.  The Manufacturer shall not be liable for any damage or loss whatsoever, whether directly, incidentally, consequentially or otherwise, caused by the malfunction of the Product due to accessories, products, and attachments of others, including batteries, used in conjunction with the Product.
The Manufacturer shall have no liability for any personal and/or bodily injury and/or property damage, or death or other loss whether direct, indirect, incidentally, consequentially or otherwise, based on a claim that the Product failed to function.  However, if the Manufacturer is held liable, whether directly or indirectly, for any loss or damage arising under this limited warranty or otherwise, regardless of cause or origin, the Manufacturer’s maximum liability shall not in any case exceed the purchase price of this Product, which shall be fixed as liquidated damages and not as a

 

 

· 6.5 to 36 VDC Operation    10 Rated Outputs

· All Temperature Rated    Any Sensor Type Input

· SAE 3.25” Diameter—Fits most engine panels

· Completely Sealed from Moisture (submersible)

· NOT POWER WASH PROOF (read above)

Specifications:

· Gas or Diesel Engine           Bright RED LED Display

· Easy to Program

· Hardware, wiring harness mounting hardware, gasket and instruction sheet included.

· This is a sensor that reads outputs, this does not control the engine or machine in any way.
CALL 1-866-736 6839 today to order!

Text Box: Auto Feed Plus®
Text Box: © 2003-7  Electronic Solutions Of Harrison, LLC
Text Box: Step One—Calibration
Press and hold BOTH push buttons until you see “HOUR,” the amount of hours, then a blank 
display (about 4 seconds).
Now release the buttons. You will see “CAL” 
displayed then a CAL number. 
Enter the Calibration Number (1-200)
After step one, press the RIGHT button to
 increase the number, press the LEFT button to decrease the number shown in the read-out.
For the Kohler engine, “CAL” is 9.1.
Text Box: Turning your Auto-Feed On or Off
If you need to turn your auto feed off, simply press and hold the left button for 4 seconds, then release.  
To turn it back on, press and hold the right button for 4 seconds.
Text Box: Step Two—Setting the HI Limit
Press and release both buttons again.  
You will now see HI displayed.
Enter the Hi or Feed On RPM number by:
Pressing the RIGHT button to increase  the number in the read-out, OR
Press the LEFT button to decrease the Text Box: Step Three—Setting the Lo Limit
Press and release both buttons again. 
You will now see Lo displayed.
Enter the Lo or Feed Off  RPM number by:
Pressing the RIGHT button to increase  the number in the read-out, OR
Press the LEFT button to decrease the 
number.  
Text Box: Step Six—Setting TYPE 
(Reversing or Non-Reversing)
Press and release both buttons again. 
You will now see “TYPE” displayed.
Enter TYPE 0 or 1
Use TYPE 0 for standard Auto-feed.
Use TYPE 1 for new style reverse.
Step Six—Exit Program Mode 
Press both buttons again, now display 
will read SET!  Unit is now programmed.

Revised June 20,  2007

Text Box: © 2007, 2008 and 2009  Electronic Solutions Of Harrison LLC
Text Box: -
Text Box: +
Text Box: -
Text Box: +
Text Box: -
Text Box: +
Text Box: -
Text Box: +
Text Box: -
Text Box: +
Text Box: -
Text Box: +
Text Box: -
Text Box: +
Text Box: -
Text Box: +
Text Box: -
Text Box: +
Text Box: -
Text Box: +
Text Box: -
Text Box: +
Text Box: -
Text Box: +
Text Box: -
Text Box: +
Text Box: Step Five  — Setting the DELAY Mode
Press and release both buttons again.
You will now see dEL displayed.
Enter the Delay Time
Enter  O for no delay
Enter 1 for a preset delay
Pressing the RIGHT button to increase  the number in the read-out, OR
Press the LEFT button to decrease the